 ST16C580
UART WITH 16-BYTE FIFO's AND INFRARED (IrDA) ENCODER/DECODER
September 2003
GENERAL DESCRIPTION
The ST16C5801 is a universal asynchronous receiver and transmitter (UART) and is pin compatible with the ST16C550 UART. The 580 is an enhanced UART with 16 byte FIFO's, automatic hardware/software flow control, and data rates up to 1.5Mbps. Onboard status registers provide the user with error indications and operational status. Modem interface control is included and can be optionally configured to operate with the Infrared (IrDA) encoder/decoder. The system interrupts may be tailored to meet user requirements. An internal loop-back capability allows onboard diagnostics. The 580 is available in 40 pin PDIP, 44 pin PLCC, and 48 pin TQFP packages. It is fabricated in an advanced CMOS process to achieve low drain power and high speed requirements.
FEATURES
* Pin to pin and functionally compatible to the Industry Standard 16550 * 2.97 to 5.5 volt operation * 1.5 Mbps transmit/receive operation (24MHz) * 16 byte transmit FIFO * 16 byte receive FIFO with error flags * Automatic hardware/software flow control * Programmable Xon/Xoff characters * Independent transmit and receive control * Software selectable Baud Rate Generator prescaleable clock rates of 1X or 4X * Four selectable transmit/receive FIFO interrupt trigger levels * Standard modem interface or Infrared IrDA encode/ decoder interface * Sleep mode ( 200A stand-by ) * Low operating current ( 1.2mA typ.)
PLCC Package
-DSR 41 -CTS 40 39 38 37 36 35 VCC N.C. -CD 42 -RI 43 D4 D3 D2 D1 D0
D5 D6 D7 RCLK RX N.C. TX CS0 CS1 -CS2 -BAUDOUT
7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
44
6
5
4
3
2
1
RESET -OP1 -DTR -RTS -OP2 N.C. INT -RXRDY A0 A1 A2
XR16C580CJ44
34 33 32 31 30 29
XTAL1
XTAL2
IOW
-IOW
GND
-IOR
-DDIS
ORDERING INFORMATION
Part number Package Operating temp Device Status
ST16C580CP40 ST16C580CJ44 ST16C580CQ48 ST16C580IP40 ST16C580IJ44 ST16C580IQ48
40-Lead 44-Lead 48-Lead 40-Lead 44-Lead 48-Lead
PDIP PLCC TQFP PDIP PLCC TQFP
0 C to + 70 C 0 C to + 70 C 0 C to + 70 C -40 C to + 85 C -40 C to + 85 C -40 C to + 85 C
Discontinued. Discontinued. Active Discontinued. Discontinued. Active
See the ST16C580CQ48 for a replacement. See the ST16C580CQ48 for a replacement. See the ST16C580IQ48 for a replacement. See the ST16C580IQ48 for a replacement.
*Note 1 Covered by U.S. Patent #5,649,122.
Rev. 1.20
EXAR Corporation, 48720 Kato Road, Fremont, CA 94538 * (510) 668-7000 * FAX (510) 668-7017
-TXRDY
N.C.
IOR
-AS
ST16C580
Figure 1, PACKAGE DESCRIPTION, 16C580
48 Pin TQFP Package
-DSR -CTS VCC N.C. N.C. -CD
40 Pin DIP Package
-RI
D4
D3
D2
D1
D0
48
47
46
45
44
43
42
41
40
39
38
37
D0 D1
1 2 3 4 5 6 7
40 39 38 37 36 35 34
VCC -RI -CD -DSR -CTS RESET -OP1 -DTR -RTS -OP2 INT -RXRDY A0 A1 A2 -AS -TXRDY -DDIS IOR -IOR
N.C. D5 D6 D7 RCLK N.C. RX TX CS0 CS1 -CS2 -BAUDOUT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
36 35 34 33 32
N.C. RESET
D2 D3
-OP1
D4
-DTR -RTS -OP2 INT -RXRDY A0 A1 A2 N.C.
D5 D6 D7 RCLK RX TX CS0 CS1 -CS2 -BAUDOUT XTAL1 XTAL2 -IOW IOW GND
30 29 28 27 26 25
8 9 10 11 12 13 14 15 16 17 18 19 20
XR16C580CP40
XR16C580CQ48
31
33 32 31 30 29 28 27 26 25 24 23 22 21
GND
IOR
Rev. 1.20
2
-TXRDY
XTAL1
XTAL2
-DDIS
N.C.
IOW
-IOW
-IOR
N.C.
-AS
ST16C580
Figure 2, BLOCK DIAGRAM
D0-D7 -IOR,IOR -IOW,IOW RESET
Data bus & Control Logic
Transmit FIFO Registers
Transmit Shift Register
TX
Flow Control Logic Receive FIFO Registers
Ir Encoder
Inter Connect Bus Lines & Control signals
A0-A2 -AS CS0,CS1 -CS2 -DDIS
Register Select Logic
Receive Shift Register
RX
Flow Control Logic
Ir Decoder
INT -RXRDY -TXRDY
Interrupt Control Logic
-DTR,-RTS -OP1,-OP2 Clock & Baud Rate Generator Modem Control Logic -CTS -RI -CD -DSR
XTAL1 RCLK XTAL2 -BAUDOUT
Rev. 1.20
3
ST16C580
SYMBOL DESCRIPTION
Symbol 40 A0 A1 A2 IOR 28 27 26 22
Pin 44 31 30 29 25
48 28 27 26 20
Signal type I I I I
Pin Description Address-0 Select Bit - Internal registers address selection. Address-1 Select Bit Internal registers address selection. Address-2 Select Bit Internal registers address selection. Read strobe. Its function is the same as -IOR (see -IOR), except it is active high. Either an active -IOR or IOR is required to transfer data from 580 to CPU during a read operation. Chip Select-0. A logical 1 on this pin provides the chip select 0 function. Chip Select-1. A logical 1 on this pin provides the chip select 1 function. Chip Select -2. A logical 0 on this pin provides the chip select 2 function. Write strobe. A logic 1 transition creates a write strobe. Its function is the same as -IOW (see -IOW), but it acts as an active high input signal. Either -IOW or IOW is required to transfer data from the CPU to 580 during a write operation. Address Strobe. A logic 0 transition on -AS latches the state of the chip selects and the register select bits, A0-A2. This input is used when address and chip selects are not stable for the duration of a read or write operation, i.e., a microprocessor that needs to de-multiplex the address and data bits. If not required, the -AS input can be permanently tied to a logic 0 (it is edge triggered).
CS0
12
14
9
I
CS1
13
15
10
I
-CS2
14
16
11
I
IOW
19
21
17
I
-AS
25
28
24
I
D0-D7
1-8
2-9
43-47 2-4
I/O
Data Bus (Bi-directional) - These pins are the eight bit, three state data bus for transferring information to or from the controlling CPU. D0 is the least significant bit and the first data bit in a transmit or receive serial data stream. Signal and Power Ground.
GND
20
22
18
Pwr
Rev. 1.20
4
ST16C580
SYMBOL DESCRIPTION
Symbol 40 -IOR 21
Pin 44 24
48 19
Signal type I
Pin Description Read strobe (active low strobe). A logic 0 on this pin transfers the contents of the 580 data bus to the CPU. Write strobe (active low strobe) - A logic 0 on this pin transfers the contents of the CPU data bus to the addressed internal register. Interrupt Request. Receive Ready. A logic 0 indicates receive data ready status, i.e. the RHR is full or the FIFO has one or more RX characters available for unloading. This pin goes to a logic 0 when the FIFO/RHR is full or when there are more characters available in either the FIFO or RHR. Transmit Ready. Buffer ready status is indicated by a logic 0, i.e., at least one location is empty and available in the FIFO or THR. This pin goes to a logic 1 when there are no more empty locations in the FIFO or THR. Baud Rate Generator Output. This pin provides the 16X clock of the selected data rate from the baud rate generator. The RCLK pin must be connected externally to -BAUDOUT when the receiver is operating at the same data rate. Drive Disable. This pin goes to a logic 0 when the external CPU is reading data from the 580. This signal can be used to disable external transceivers or other logic functions. Output-1 (User Defined) - See bit-2 of modem control register (MCR bit-2). Output-2 (User Defined). This pin provides the user a general purpose output. See bit-3 modem control register (MCR bit-3). Receive Clock Input. This pin is used as external 16X clock input to the receiver section. External connection to Baudout pin is required in order to utilize the internal baud rate generator.
-IOW
18
20
16
I
INT -RXRDY
30 29
33 32
30 29
O O
-TXRDY
24
27
23
O
-BAUDOUT
15
17
12
O
-DDIS
23
26
22
O
-OP1
34
38
34
O
-OP2
31
35
31
O
RCLK
9
10
5
I
Rev. 1.20
5
ST16C580
SYMBOL DESCRIPTION
Symbol 40 RESET 35
Pin 44 39
48 35
Signal type I
Pin Description Reset. (active high) - A logic 1 on this pin will reset the internal registers and all the outputs. The UART transmitter output and the receiver input will be disabled during reset time. (See ST16C580 External Reset Conditions for initialization details.) Power Supply Input. Crystal or External Clock Input - Functions as a crystal input or as an external clock input. A crystal can be connected between this pin and XTAL2 to form an internal oscillator circuit. An external 1 M resistor is required between the XTAL1 and XTAL2 pins (see figure 9). Alternatively, an external clock can be connected to this pin to provide custom data rates (Programming Baud Rate Generator section). Output of the Crystal Oscillator or Buffered Clock - (See also XTAL1). Crystal oscillator output or buffered clock output. Carrier Detect (active low) - A logic 0 on this pin indicates that a carrier has been detected by the modem. Clear to Send (active low) - A logic 0 on the -CTS pin indicates the modem or data set is ready to accept transmit data from the 580. Status can be tested by reading MSR bit4. This pin only affects the transmit and receive operations when Auto CTS function is enabled via the Enhanced Feature Register (EFR) bit-7, for hardware flow control operation. Data Set Ready (active low) - A logic 0 on this pin indicates the modem or data set is powered-on and is ready for data exchange with the UART. This pin has no effect on the UART's transmit or receive operation. Data Terminal Ready (active low) - A logic 0 on this pin indicates that the 580 is powered-on and ready. This pin can be controlled via the modem control register. Writing a logic 1 to MCR bit-0 will set the -DTR output to logic 0, enabling the modem. This pin will be a logic 1 after writing a logic 0 to MCR bit-0, or after a reset. This pin has no effect on the
VCC XTAL1
40 16
44 18
42 14
Pwr I
XTAL2
17
19
15
O
-CD
38
42
40
I
-CTS
36
40
38
I
-DSR
37
41
39
I
-DTR
33
37
33
O
Rev. 1.20
6
ST16C580
SYMBOL DESCRIPTION
Symbol 40
Pin 44
48
Signal type
Pin Description UART's transmit or receive operation.
-RI
39
43
41
I
Ring Indicator (active low) - A logic 0 on this pin indicates the modem has received a ringing signal from the telephone line. A logic 1 transition on this input pin will generate an interrupt. Request to Send (active low) - A logic 0 on the -RTS pin indicates the transmitter has data ready and waiting to send. Writing a logic 1 in the modem control register (MCR bit-1) will set this pin to a logic 0 indicating data is available. After a reset this pin will be set to a logic 1. This pin only affects the transmit and receive operations when Auto RTS function is enabled via the Enhanced Feature Register (EFR) bit-6, for hardware flow control operation. Receive Data - This pin provides the serial receive data input to the 580. Two user selectable interface options are available. The first option supports the standard modem interface. The second option provides an Infrared decoder interface, see figures 2/3. When using the standard modem interface, the RX signal will be a logic 1 during reset, idle (no data), or when the transmitter is disabled. The inactive state (no data) for the Infrared decoder interface is a logic 0. MCR bit-6 selects the standard modem or infrared interface. During the local loop-back mode, the RX input pin is disabled and TX data is internally connected to the UART RX Input, internally, see figure 12. Transmit Data - This pin provides the serial transmit data from the 580. Two user selectable interface options are available. The first user option supports a standard modem interface. The second option provides an Infrared encoder interface, see figures 2/3. When using the standard modem interface, the TX signal will be a logic 1 during reset, idle (no data), or when the transmitter is disabled. The inactive state (no data) for the Infrared encoder/ decoder interface is a Logic 0. MCR bit-6 selects the standard modem or infrared interface. During the local loop-back mode, the TX input pin is disabled and TX data is internally connected to the UART RX Input, see figure 12.
-RTS
32
36
32
O
RX / IRRX
10
11
7
I
TX / IRTX
11
13
8
O
Rev. 1.20
7
ST16C580
GENERAL DESCRIPTION
The 580 provides serial asynchronous receive data synchronization, parallel-to-serial and serial-to-parallel data conversions for both the transmitter and receiver sections. These functions are necessary for converting the serial data stream into parallel data that is required with digital data systems. Synchronization for the serial data stream is accomplished by adding start and stops bits to the transmit data to form a data character (character orientated protocol). Data integrity is insured by attaching a parity bit to the data character. The parity bit is checked by the receiver for any transmission bit errors. The electronic circuitry to provide all these functions is fairly complex especially when manufactured on a single integrated silicon chip. The ST16C580 represents such an integration with greatly enhanced features. The 580 is fabricated with an advanced CMOS process. The 580 is an upward solution that provides 16 bytes of transmit and receive FIFO memory, instead of 16 bytes provided in the 16C550, or none in the 16C450. The 580 is designed to work with high speed modems and shared network environments, that require fast data processing time. Increased performance is realized in the 580 by the larger transmit and receive FIFO's. This allows the external processor to handle more networking tasks within a given time. In addition, the 4 selectable levels of FIFO trigger interrupt and automatic hardware/software flow control is uniquely provided for maximum data throughput performance especially when operating in a multi-channel environment. The combination of the above greatly reduces the bandwidth requirement of the external controlling CPU, increases performance, and reduces power consumption. The 580 is capable of operation to 1.5Mbps with a 24 MHz crystal or external clock input. With a crystal of 7.3728 MHz and through a software option, the user can select data rates up to 460.8Kbps. The rich feature set of the 580 is available through internal registers. Automatic hardware/software flow control, selectable transmit and receive FIFO trigger levels, selectable TX and RX baud rates, infrared encoder/decoder interface, modem interface controls, and a sleep mode are all standard features. Following a power on reset or an external reset, the 580 is software compatible with previous generation of UARTs, 16C450 and 16C550.
FUNCTIONAL DESCRIPTIONS
Internal Registers The 580 provides 15 internal registers for monitoring and control. These registers are shown in Table 3 below. Twelve registers are similar to those already available in the standard 16C550. These registers function as data holding registers (THR/RHR), interrupt status and control registers (IER/ISR), a FIFO control register (FCR), line status and control registers, (LCR/LSR), modem status and control registers (MCR/MSR), programmable data rate (clock) control registers (DLL/DLM), and a user assessable scratchpad register (SPR). Beyond the general 16C550 features and capabilities, the 580 offers an enhanced feature register set (EFR, Xon/Xoff 1-2) that provides on board hardware/software flow control. Register functions are more fully described in the following paragraphs.
Table 3, INTERNAL REGISTER
Rev. 1.20
8
ST16C580
DECODE
A2 A1 A0 READ MODE WRITE MODE
General Register Set (THR/RHR, IER/ISR, MCR/MSR, LCR/LSR, SPR): 0 0 0 0 1 1 1 1 0 0 1 1 0 0 1 1 0 1 0 1 0 1 0 1 Receive Holding Register Interrupt Status Register Transmit Holding Register Interrupt Enable Register FIFO Control Register Line Control Register Modem Control Register
Line Status Register Modem Status Register Scratchpad Register
Scratchpad Register
Baud Rate Register Set (DLL/DLM): Note *3 0 0 0 0 0 1 LSB of Divisor Latch MSB of Divisor Latch LSB of Divisor Latch MSB of Divisor Latch
Enhanced Register Set (EFR, Xon/off 1-2): Note *4 0 1 1 1 1 1 0 0 1 1 0 0 1 0 1 Enhanced Feature Register Xon-1 Word Xon-2 Word Xoff-1 Word Xoff-2 Word Enhanced Feature Register Xon-1 Word Xon-2 Word Xoff-1 Word Xoff-2 Word
Note *3: These registers are accessible only when LCR bit-7 is set to a logic 1. Note *4: Enhanced Feature Register, Xon 1,2 and Xoff 1,2 are accessible only when the LCR is set to "BF" (HEX).
Rev. 1.20
9
ST16C580
FIFO Operation The 16 byte transmit and receive data FIFO's are enabled by the FIFO Control Register (FCR) bit-0. With 16C550 devices, the user can set the receive trigger level but not the transmit trigger level. The 580 provides independent trigger levels for both receiver and transmitter. To remain compatible with ST16C550, the transmit interrupt trigger level is set to 1 following a reset. It should be noted that the user can set the transmit trigger levels by writing to the FCR register, but activation will not take place until EFR bit4 is set to a logic 1. The receiver FIFO section includes a time-out function to ensure data is delivered to the external CPU. An interrupt is generated whenever the Receive Holding Register (RHR) has not been read following the loading of a character or the receive trigger level has not been reached. (see hardware flow control for a description of this timing).
Hardware Flow Control When automatic hardware flow control is enabled, the 580 monitors the -CTS pin for a remote buffer overflow indication and controls the -RTS pin for local buffer overflows. Automatic hardware flow control is selected by setting bits 6 (RTS) and 7 (CTS) of the EFR register to a logic 1. If -CTS transitions from a logic 0 to a logic 1 indicating a flow control request, ISR bit5 will be set to a logic 1 (if enabled via IER bit 6-7), and the 580 will suspend TX transmissions as soon as the stop bit of the character in process is shifted out. Transmission is resumed after the -CTS input returns to a logic 0, indicating more data may be sent. With the Auto RTS function enabled, an interrupt is generated when the receive FIFO reaches the programmed trigger level. The -RTS pin will not be forced to a logic 1 (RTS Off), until the receive FIFO reaches the next trigger level. However, the -RTS pin will return to a logic 0 after the data buffer (FIFO) is unloaded to the next trigger level below the programmed trigger level. However, under the above described conditions the 580 will continue to accept data until the receive FIFO is full.
Selected INT Trigger Pin Level Activation (characters) 1 4 8 14 1 4 8 14
-RTS Logic "1" (characters)
-RTS Logic "0" (characters)
4 8 14 14
0 1 4 8
Rev. 1.20
10
ST16C580
Software Flow Control When software flow control is enabled, the 580 compares one or two sequential receive data characters with the programmed Xon or Xoff-1,2 character value(s). If receive character(s) (RX) match the programmed values, the 580 will halt transmission (TX) as soon as the current character(s) has completed transmission. When a match occurs, the receive ready (if enabled via Xoff IER bit-5) flags will be set and the interrupt output pin (if receive interrupt is enabled) will be activated. Following a suspension due to a match of the Xoff characters values, the 580 will monitor the receive data stream for a match to the Xon-1,2 character value(s). If a match is found, the 580 will resume operation and clear the flags (ISR bit4). Reset initially sets the contents of the Xon/Xoff 8-bit flow control registers to a logic 0. Following reset the user can write any Xon/Xoff value desired for software flow control. Different conditions can be set to detect Xon/Xoff characters and suspend/resume transmissions. When double 8-bit Xon/Xoff characters are selected, the 580 compares two consecutive receive characters with two software flow control 8-bit values (Xon1, Xon2, Xoff1, Xoff2) and controls TX transmissions accordingly. Under the above described flow control mechanisms, flow control characters are not placed (stacked) in the user accessible RX data buffer or FIFO. In the event that the receive buffer is overfilling and flow control needs to be executed, the 580 automatically sends an Xoff message (when enabled) via the serial TX output to the remote modem. The 580 sends the Xoff-1,2 characters as soon as received data passes the programmed trigger level. To clear this condition, the 580 will transmit the programmed Xon1,2 characters as soon as receive data drops below the programmed trigger level. Special Feature Software Flow Control A special feature is provided to detect an 8-bit character when bit-5 is set in the Enhanced Feature Register (EFR). When this character is detected, it will be
placed on the user accessible data stack along with normal incoming RX data. This condition is selected in conjunction with EFR bits 0-3. Note that software flow control should be turned off when using this special mode by setting EFR bit 0-3 to a logic 0. The 580 compares each incoming receive character with Xoff-2 data. If a match exists, the received data will be transferred to FIFO and ISR bit-4 will be set to indicate detection of special character (see Figure 9). Although the Internal Register Table shows each XRegister with eight bits of character information, the actual number of bits is dependent on the programmed word length. Line Control Register (LCR) bits 0-1 defines the number of character bits, i.e., either 5 bits, 6 bits, 7 bits, or 8 bits. The word length selected by LCR bits 0-1 also determines the number of bits that will be used for the special character comparison. Bit-0 in the X-registers corresponds with the LSB bit for the receive character. Time-out Interrupts Three special interrupts have been added to monitor the hardware and software flow control. The interrupts are enabled by IER bits 5-7. Care must be taken when handling these interrupts. Following a reset the transmitter interrupt is enabled, the 580 will issue an interrupt to indicate that transmit holding register is empty. This interrupt must be serviced prior to continuing operations. The LSR register provides the current singular highest priority interrupt only. It could be noted that CTS and RTS interrupts have lowest interrupt priority. A condition can exist where a higher priority interrupt may mask the lower priority CTS/ RTS interrupt(s). Only after servicing the higher pending interrupt will the lower priority CTS/ RTS interrupt(s) be reflected in the status register. Servicing the interrupt without investigating further interrupt conditions can result in data errors. When two interrupt conditions have the same priority, it is important to service these interrupts correctly. Receive Data Ready and Receive Time Out have the same interrupt priority (when enabled by IER bit-3). The receiver issues an interrupt after the number of characters have reached the programmed trigger
Rev. 1.20
11
ST16C580
level. In this case the 580 FIFO may hold more characters than the programmed trigger level. Following the removal of a data byte, the user should recheck LSR bit0 for additional characters. A Receive Time Out will not occur if the receive FIFO is empty. The time out counter is reset at the center of each stop bit received or each time the receive holding register (RHR) is read (see Figure 10, Receive Time-out Interrupt). The actual time out value is T (Time out length in bits) = 4 X P (Programmed word length) + 12. To convert the time out value to a character value, the user has to consider the complete word length, including data information length, start bit, parity bit, and the size of stop bit, i.e., 1X, 1.5X, or 2X bit times. Example -A: If the user programs a word length of 7, with no parity and one stop bit, the time out will be: T = 4 X 7( programmed word length) +12 = 40 bit times. The character time will be equal to 40 / 9 = 4.4 characters, or as shown in the fully worked out example: T = [(programmed word length = 7) + (stop bit = 1) + (start bit = 1) = 9]. 40 (bit times divided by 9) = 4.4 characters. Example -B: If the user programs the word length = 7, with parity and one stop bit, the time out will be: T = 4 X 7(programmed word length) + 12 = 40 bit times. Character time = 40 / 10 [ (programmed word length = 7) + (parity = 1) + (stop bit = 1) + (start bit = 1) = 4 characters. Programmable Baud Rate Generator
The 580 can be configured for internal or external clock operation. For internal clock oscillator operation, an industry standard microprocessor crystal (parallel resonant/ 22-33 pF load) is connected externally between the XTAL1 and XTAL2 pins, with an external 1 M resistor across it. Alternatively, an external clock can be connected to the XTAL1 pin to clock the internal baud rate generator for standard or custom rates. The generator divides the input 16X clock by any divisor from 1 to 216 -1. The 580 divides the basic crystal or external clock by 16. Further division of this 16X clock provides two table rates to support low and high data rate applications using the same system design. The two rate tables are selectable through the internal register, MCR bit-7. Setting MCR bit-7 to a logic 1 provides an additional divide by 4 whereas, setting MCR bit-7 to a logic 0 only divides by 1. (See Table 4 and Figure 11). The frequency of the BAUDOUT output pin is exactly 16X (16 times) of the selected baud rate (-BAUDOUT =16 x Baud Rate). Customized Baud Rates can be achieved by selecting the proper divisor values for the MSB and LSB sections of baud rate generator. Programming the Baud Rate Generator Registers
Crystal oscillator connection
XTAL1
The 580 supports high speed modem technologies that have increased input data rates by employing data compression schemes. For example a 33.6Kbps modem that employs data compression may require a 115.2Kbps input data rate. A 128.0Kbps ISDN modem that supports data compression may need an input data rate of 460.8Kbps. The 580 can support a standard data rate of 921.6Kbps. Single baud rate generator is provided for the transmitter and receiver, allowing independent TX/RX channel control. The programmable Baud Rate Generator is capable of accepting an input clock up to 24 MHz, as required for supporting a 1.5Mbps data rate.
XTAL2 R1 50-120 R2 1M X1 1.8432 MHz C1 22pF C2 33pF
Rev. 1.20
12
ST16C580
DLM (MSB) and DLL (LSB) provides a user capability for selecting the desired final baud rate. The example in Table 4 below, shows the two selectable baud rate tables available when using a 7.3728 MHz crystal.
Table 4, BAUD RATE GENERATOR PROGRAMMING TABLE (7.3728 MHz CLOCK):
Output Baud Rate MCR BIT-7=1 50 75 150 300 600 1200 2400 4800 7200 9600 19.2k 38.4k 57.6k 115.2k
Output Baud Rate MCR Bit-7=0 200 300 600 1200 2400 4800 9600 19.2K 28.8K 38.4k 76.8k 153.6k 230.4k 460.8k
User 16 x Clock Divisor (Decimal) 2304 1536 768 384 192 96 48 24 16 12 6 3 2 1
User 16 x Clock Divisor (HEX) 900 600 300 180 C0 60 30 18 10 0C 06 03 02 01
DLM Program Value (HEX) 09 06 03 01 00 00 00 00 00 00 00 00 00 00
DLL Program Value (HEX) 00 00 00 80 C0 60 30 18 10 0C 06 03 02 01
Crystal oscillator or External clock 1X / 4X selection
Divide by 1 logic MCR Bit-7=0 Baudrate Generator Logic MCR Bit-7=1
XTAL1 XTAL2
Clock Oscillator Logic
-BAUDOUT
Divide by 4 logic
Rev. 1.20
13
ST16C580
DMA Operation The 580 FIFO trigger level provides additional flexibility to the user for block mode operation. LSR bits 5-6 provide an indication when the transmitter is empty or has an empty location(s). The user can optionally operate the transmit and receive FIFO's in the DMA mode (FCR bit-3). When the transmit and receive FIFO's are enabled and the DMA mode is deactivated (DMA Mode "0"), the 580 activates the interrupt output pin for each data transmit or receive operation. When DMA mode is activated (DMA Mode "1"), the user takes the advantage of block mode operation by loading or unloading the FIFO in a block sequence determined by the preset trigger level. In this mode, the 580 sets the interrupt output pin when characters in the transmit FIFO's are below the transmit trigger level, or the characters in the receive FIFO's are above the receive trigger level. Sleep Mode The 580 is designed to operate with low power consumption. A special sleep mode is included to further reduce power consumption when the chip is not being used. With EFR bit-4 and IER bit-4 enabled (set to a logic 1), the 580 enters the sleep mode but resumes normal operation when a start bit is detected, a change of state on any of the modem input pins RX, -RI, -CTS, -DSR, -CD, or transmit data is provided by the user. If the sleep mode is enabled and the 580 is awakened by one of the conditions described above, it will return to the sleep mode automatically after the last character is transmitted or read by the user. In any case, the sleep mode will not be entered while an interrupt(s) is pending. The 580 will stay in the sleep mode of operation until it is disabled by setting IER bit-4 to a logic 0. Loop-back Mode The internal loop-back capability allows onboard diagnostics. In the loop-back mode the normal modem interface pins are disconnected and reconfigured for loop-back internally. In this mode MSR bits 4-7 are also disconnected. However, MCR register bits 0-3 can be used for controlling loop-back diagnostic test-
ing. In the loop-back mode OP1 and OP2 in the MCR register (bits 0-1) control the modem -RI and -CD inputs respectively. MCR signals -DTR and -RTS (bits 0-1) are used to control the modem -CTS and -DSR inputs respectively. The transmitter output (TX) and the receiver input (RX) are disconnected from their associated interface pins, and instead are connected together internally (See Figure 12). The -CTS, -DSR, -CD, and -RI are disconnected from their normal modem control inputs pins, and instead are connected internally to -DTR, -RTS, -OP1 and -OP2. Loop-back test data is entered into the transmit holding register via the user data bus interface, D0-D7. The transmit UART serializes the data and passes the serial data to the receive UART via the internal loop-back connection. The receive UART converts the serial data back into parallel data that is then made available at the user data interface, D0-D7. The user optionally compares the received data to the initial transmitted data for verifying error free operation of the UART TX/RX circuits. In this mode , the receiver and transmitter interrupts are fully operational. The Modem Control Interrupts are also operational. However, the interrupts can only be read using lower four bits of the Modem Control Register (MCR bits 0-3) instead of the four Modem Status Register bits 4-7. The interrupts are still controlled by the IER.
Rev. 1.20
14
ST16C580
Figure 12, INTERNAL LOOP-BACK MODE DIAGRAM
Flow Control Logic Receive FIFO Registers
Ir Encoder
Receive Shift Register
MCR Bit-4=1 RX -RTS -CD -DTR -RI -OP1 -DSR -OP2 -CTS
D0-D7 -IOR,IOR -IOW,IOW RESET
Data bus & Control Logic
Transmit FIFO Registers
Transmit Shift Register
TX
A0-A2 -AS CS0,CS1 -CS2 -DDIS
I n te r C o n n e c t B u s L in e s & C o n tr o l s ig n a ls
Register Select Logic
Flow Control Logic
Ir Decoder
XTAL1 RCLK XTAL2 -BAUDOUT
Rev. 1.20
15
Clock & Baud Rate Generator
Modem Control Logic
INT -RXRDY -TXRDY
Interrupt Control Logic
ST16C580
REGISTER FUNCTIONAL DESCRIPTIONS
The following table delineates the assigned bit functions for the fifteen 580 internal registers. The assigned bit functions are more fully defined in the following paragraphs.
Table 5, ST16C580 INTERNAL REGISTERS
A2 A1 A0 Register [Default] Note *5 BIT-7 BIT-6 BIT-5 BIT-4 BIT-3 BIT-2 BIT-1 BIT-0
General Register Set
0 0 0 0 0 0 0 0 1 RHR [XX] THR [XX] IER [00] bit-7 bit-7 CTS interrupt bit-6 bit-6 RTS interrupt bit-5 bit-5 Xoff interrupt bit-4 bit-4 Sleep mode bit-3 bit-3 modem status interrupt bit-2 bit-2 receive line status interrupt XMIT FIFO reset INT priority bit-1 stop bits bit-1 bit-1 transmit holding register bit-0 bit-0 receive holding register
0
1
0
FCR [00]
RCVR trigger (MSB) FIFO's enabled
RCVR trigger (LSB) FIFO's enabled
TX trigger (MSB) INT priority bit-4 set parity
TX trigger (LSB) INT priority bit-3 even parity
DMA mode select INT priority bit-2 parity enable
RCVR FIFO reset INT priority bit-0 word length bit-1 -RTS
FIFO enable
0
1
0
ISR [01]
INT status
0
1
1
LCR [00]
divisor latch enable Clock select
set break
word length bit-0 -DTR
1
0
0
MCR [00]
IR enable
0
loop back
-OP2
-OP1
1
0
1
LSR [60]
FIFO data error CD
trans. empty
trans. holding empty DSR
break interrupt
framing error
parity error
overrun error
receive data ready delta -CTS bit-0
1
1
0
MSR [X0]
RI
CTS
delta -CD bit-3
delta -RI bit-2
delta -DSR bit-1
1
1
1
SPR [FF]
bit-7
bit-6
bit-5
bit-4
Special Register Set: Note *3
0 0 0 0 0 1 DLL [XX] DLM [XX] bit-7 bit-15 bit-6 bit-14 bit-5 bit-13 bit-4 bit-12 bit-3 bit-11 bit-2 bit-10 bit-1 bit-9 bit-0 bit-8
Rev. 1.20
16
ST16C580
A2 A1 A0
Register [Default] Note *5
BIT-7
BIT-6
BIT-5
BIT-4
BIT-3
BIT-2
BIT-1
BIT-0
Enhanced Register Set: Note *4
0 1 0 EFR [00] Auto CTS Auto RTS Special Char. select Enable IER Bits 4-7, ISR, FCR Bits 4-5, MCR Bits 5-7 bit-4 bit-12 bit-4 bit-12 Cont-3 Tx,Rx Control Cont-2 Tx,Rx Control Cont-1 Tx,Rx Control Cont-0 Tx,Rx Control
1 1 1 1
0 0 1 1
0 1 0 1
Xon-1 [00] Xon-2 [00] Xoff-1 [00] Xoff-2 [00]
bit-7 bit-15 bit-7 bit-15
bit-6 bit-14 bit-6 bit-14
bit-5 bit-13 bit-5 bit-13
bit-3 bit-11 bit-3 bit-11
bit-2 bit-10 bit-2 bit-10
bit-1 bit-9 bit-1 bit-9
bit-0 bit-8 bit-0 bit-8
Note *3: The Special register set is accessible only when LCR bit-7 is set to a logic 1. Note *4: Enhanced Feature Register, Xon 1,2 and Xoff 1,2 are accessible only when LCR is set to "BF" Hex Note *5: The value represents the register's initialized HEX value. An "X" signifies a 4-bit un-initialize nibble.
Rev. 1.20
17
ST16C580
Transmit and Receive Holding Register The serial transmitter section consists of an 8-bit Transmit Hold Register (THR) and Transmit Shift Register (TSR). The status of the THR is provided in the Line Status Register (LSR). Writing to the THR transfers the contents of the data bus (D7-D0) to the THR, providing that the THR or TSR is empty. The THR empty flag in the LSR register will be set to a logic 1 when the transmitter is empty or when data is transferred to the TSR. Note that a write operation can be performed when the transmit holding register empty flag is set (logic 0 = FIFO full, logic 1= at least one FIFO location available). The serial receive section also contains an 8-bit Receive Holding Register, RHR. Receive data is removed from the 580 and receive FIFO by reading the RHR register. The receive section provides a mechanism to prevent false starts. On the falling edge of a start or false start bit, an internal receiver counter starts counting clocks at 16x clock rate. After 7 1/2 clocks the start bit time should be shifted to the center of the start bit. At this time the start bit is sampled and if it is still a logic 0 it is validated. Evaluating the start bit in this manner prevents the receiver from assembling a false character. Receiver status codes will be posted in the LSR. Interrupt Enable Register (IER) The Interrupt Enable Register (IER) masks the interrupts from receiver ready, transmitter empty, line status and modem status registers. These interrupts would normally be seen on the 580 INT output pin.
B) FIFO status will also be reflected in the user accessible ISR register when the FIFO trigger level is reached. Both the ISR register status bit and the interrupt will be cleared when the FIFO drops below the trigger level. C) The data ready bit (LSR BIT-0) is set as soon as a character is transferred from the shift register to the receive FIFO. It is reset when the FIFO is empty.
IER Vs Receive/Transmit FIFO Polled Mode Operation
When FCR BIT-0 equals a logic 1; resetting IER bits 0-3 enables the 580 in the FIFO polled mode of operation. Since the receiver and transmitter have separate bits in the LSR either or both can be used in the polled mode by selecting respective transmit or receive control bit(s). A) LSR BIT-0 will be a logic 1 as long as there is one byte in the receive FIFO. B) LSR BIT 1-4 will indicate if an overrun error occurred. C) LSR BIT-5 will indicate when the transmit FIFO is empty. D) LSR BIT-6 will indicate when both the transmit FIFO and transmit shift register are empty. E) LSR BIT-7 will indicate any FIFO data errors.
IER Vs Receive FIFO Interrupt Mode Operation
When the receive FIFO (FCR BIT-0 = a logic 1) and receive interrupts (IER BIT-0 = logic 1) are enabled, the receive interrupts and register status will reflect the following: A) The receive data available interrupts are issued to the external CPU when the FIFO has reached the programmed trigger level. It will be cleared when the FIFO drops below the programmed trigger level.
IER BIT-0: Logic 0 = Disable the receiver ready interrupt. (normal default condition) Logic 1 = Enable the receiver ready interrupt. IER BIT-1: Logic 0 = Disable the transmitter empty interrupt. (normal default condition) Logic 1 = Enable the transmitter empty interrupt. IER BIT-2: Logic 0 = Disable the receiver line status interrupt.
Rev. 1.20
18
ST16C580
(normal default condition) Logic 1 = Enable the receiver line status interrupt.
IER BIT-3: Logic 0 = Disable the modem status register interrupt. (normal default condition) Logic 1 = Enable the modem status register interrupt. IER BIT -4: Logic 0 = Disable sleep mode. (normal default condition) Logic 1 = Enable sleep mode. See Sleep Mode section for details IER BIT-5: Logic 0 = Disable the software flow control, receive Xoff interrupt. (normal default condition) Logic 1 = Enable the software flow control, receive Xoff interrupt. See Software Flow Control section for details. IER BIT-6: Logic 0 = Disable the RTS interrupt. (normal default condition) Logic 1 = Enable the RTS interrupt. The 580 issues an interrupt when the RTS pin transitions from a logic 0 to a logic 1. IER BIT-7: Logic 0 = Disable the CTS interrupt. (normal default condition) Logic 1 = Enable the CTS interrupt. The 580 issues an interrupt when CTS pin transitions from a logic 0 to a logic 1.
FIFO Control Register (FCR) This register is used to enable the FIFO's, clear the FIFO's, set the transmit/receive FIFO trigger levels, and select the DMA mode. The DMA, and FIFO modes are defined as follows:
go to a logic 0 when ever an empty transmit space is available in the Transmit Holding Register (THR). Receive Ready (-RXRDY) will go to a logic 0 whenever the Receive Holding Register (RHR) is loaded with a character. Mode 1 Set and enable the interrupt in a block mode operation. The transmit interrupt is set when the transmit FIFO is below the programmed trigger level. -TXRDY remains a logic 0 as long as one empty FIFO location is available. The receive interrupt is set when the receive FIFO fills to the programmed trigger level. However the FIFO continues to fill regardless of the programmed level until the FIFO is full. -RXRDY remains a logic 0 as long as the FIFO fill level is above the programmed trigger level.
FCR BIT-0: Logic 0 = Disable the transmit and receive FIFO. (normal default condition) Logic 1 = Enable the transmit and receive FIFO. This bit must be a "1" when other FCR bits are written to or they will not be programmed. FCR BIT-1: Logic 0 = No FIFO receive reset. (normal default condition) Logic 1 = Clears the contents of the receive FIFO and resets the FIFO counter logic (the receive shift register is not cleared or altered). This bit will return to a logic 0 after clearing the FIFO. FCR BIT-2: Logic 0 = No FIFO transmit reset. (normal default condition) Logic 1 = Clears the contents of the transmit FIFO and resets the FIFO counter logic (the transmit shift register is not cleared or altered). This bit will return to a logic 0 after clearing the FIFO. FCR BIT-3: Logic 0 = Set DMA mode "0". (normal default condition) Logic 1 = Set DMA mode "1." Transmit operation in mode "0": When the 580 is in the ST16C450 mode (FIFO's disabled, FCR bit-0 = logic 0) or in the FIFO mode
DMA MODE Mode 0 Set and enable the interrupt for each single transmit or receive operation, and is similar to the ST16C450 mode. Transmit Ready (-TXRDY) will
Rev. 1.20
19
ST16C580
(FIFO's enabled, FCR bit-0 = logic 1, FCR bit-3 = logic 0) and when there are no characters in the transmit FIFO or transmit holding register, the -TXRDY pin will be a logic 0. Once active the -TXRDY pin will go to a logic 1 after the first character is loaded into the transmit holding register.
These bits are used to set the trigger level for the receive FIFO interrupt. An interrupt is generated when the number of characters in the FIFO equals the programmed trigger level. However the FIFO will continue to be loaded until it is full.
Receive operation in mode "0": When the 580 is in mode "0" (FCR bit-0 = logic 0) or in the FIFO mode (FCR bit-0 = logic 1, FCR bit-3 = logic 0) and there is at least one character in the receive FIFO, the -RXRDY pin will be a logic 0. Once active the -RXRDY pin will go to a logic 1 when there are no more characters in the receiver. Transmit operation in mode "1": When the 580 is in FIFO mode ( FCR bit-0 = logic 1, FCR bit-3 = logic 1 ), the -TXRDY pin will be a logic 1 when the transmit FIFO is completely full. It will be a logic 0 if one or more FIFO locations are empty. Receive operation in mode "1": When the 580 is in FIFO mode (FCR bit-0 = logic 1, FCR bit-3 = logic 1) and the trigger level has been reached, or a Receive Time Out has occurred, the RXRDY pin will go to a logic 0. Once activated, it will go to a logic 1 after there are no more characters in the FIFO. FCR BIT 4-5: (logic 0 or cleared is the default condition, TX trigger level = 1) These bits are used to set the trigger level for the transmit FIFO interrupt. The ST16C580 will issue a transmit empty interrupt when the number of characters in FIFO drops below the selected trigger level.
BIT-7 0 0 1 1
BIT-6 0 1 0 1
RX FIFO trigger level 1 4 8 14
Interrupt Status Register (ISR) The 580 provides six levels of prioritized interrupts to minimize external software interaction. The Interrupt Status Register (ISR) provides the user with six interrupt status bits. Performing a read cycle on the ISR will provide the user with the highest pending interrupt level to be serviced. No other interrupts are acknowledged until the pending interrupt is serviced. Whenever the interrupt status register is read, the interrupt status is cleared. However it should be noted that only the current pending interrupt is cleared by the read. A lower level interrupt may be seen after rereading the interrupt status bits. The Interrupt Source Table 6 (below) shows the data values (bit 0-5) for the six prioritized interrupt levels and the interrupt sources associated with each of these interrupt levels:
BIT-5 0 0 1 1
BIT-4 0 1 0 1
TX FIFO trigger level 1 4 8 14
FCR BIT 6-7: (logic 0 or cleared is the default condition, RX trigger level =8)
Rev. 1.20
20
ST16C580
Table 6, INTERRUPT SOURCE TABLE Priority Level 1 2 2 3 4 5 6 [ ISR BITS ] Bit-5 Bit-4 Bit-3 Bit-2 Bit-1 Bit-0 0 0 0 0 0 0 1 0 0 0 0 0 1 0 0 0 1 0 0 0 0 1 1 1 0 0 0 0 1 0 0 1 0 0 0 0 0 0 0 0 0 0
Source of the interrupt LSR (Receiver Line Status Register) RXRDY (Received Data Ready) RXRDY (Receive Data time out) TXRDY ( Transmitter Holding Register Empty) MSR (Modem Status Register) RXRDY (Received Xoff signal)/ Special character CTS, RTS change of state
ISR BIT-0: Logic 0 = An interrupt is pending and the ISR contents may be used as a pointer to the appropriate interrupt service routine. Logic 1 = No interrupt pending. (normal default condition) ISR BIT 1-3: (logic 0 or cleared is the default condition) These bits indicate the source for a pending interrupt at interrupt priority levels 1, 2, and 3 (See Interrupt Source Table). ISR BIT 4-5: (logic 0 or cleared is the default condition) These bits are enabled when EFR bit-4 is set to a logic 1. ISR bit-4 indicates that matching Xoff character(s) have been detected. ISR bit-5 indicates that CTS, RTS have been generated. Note that once set to a logic 1, the ISR bit-4 will stay a logic 1 until Xon character(s) are received. ISR BIT 6-7: (logic 0 or cleared is the default condition) These bits are set to a logic 0 when the FIFO is not being used. They are set to a logic 1 when the FIFO's are enabled
Line Control Register (LCR) The Line Control Register is used to specify the asynchronous data communication format. The word length, the number of stop bits, and the parity are selected by writing the appropriate bits in this register.
LCR BIT 0-1: (logic 0 or cleared is the default condition) These two bits specify the word length to be transmitted or received.
BIT-1 0 0 1 1
BIT-0 0 1 0 1
Word length 5 6 7 8
LCR BIT-2: (logic 0 or cleared is the default condition) The length of stop bit is specified by this bit in conjunction with the programmed word length.
BIT-2
Word length
Stop bit length (Bit time(s)) 1 1-1/2 2
0 1 1
5,6,7,8 5 6,7,8
LCR BIT-3: Parity or no parity can be selected via this bit. Logic 0 = No parity (normal default condition) Logic 1 = A parity bit is generated during the transmission, receiver checks the data and parity for transmission errors.
Rev. 1.20
21
ST16C580
LCR BIT-4: If the parity bit is enabled with LCR bit-3 set to a logic 1, LCR BIT-4 selects the even or odd parity format. Logic 0 = ODD Parity is generated by forcing an odd number of logic 1's in the transmitted data. The receiver must be programmed to check the same format. (normal default condition) Logic 1 = EVEN Parity is generated by forcing an even the number of logic 1's in the transmitted. The receiver must be programmed to check the same format. LCR BIT-5: If the parity bit is enabled, LCR BIT-5 selects the forced parity format. LCR BIT-5 = logic 0, parity is not forced (normal default condition) LCR BIT-5 = logic 1 and LCR BIT-4 = logic 0, parity bit is forced to a logical 1 for the transmit and receive data. LCR BIT-5 = logic 1 and LCR BIT-4 = logic 1, parity bit is forced to a logical 0 for the transmit and receive data.
LCR BIT-7: The internal baud rate counter latch and Enhance Feature mode enable. Logic 0 = Divisor latch disabled. (normal default condition) Logic 1 = Divisor latch and enhanced feature register enabled.
Modem Control Register (MCR) This register controls the interface with the modem or a peripheral device.
MCR BIT-0: Logic 0 = Force -DTR output to a logic 1. (normal default condition) Logic 1 = Force -DTR output to a logic 0. MCR BIT-1: Logic 0 = Force -RTS output to a logic 1. (normal default condition) Logic 1 = Force -RTS output to a logic 0. Automatic RTS may be used for hardware flow control by enabling EFR bit-6 (See EFR bit-6). MCR BIT-2: Logic 0 = Set -OP1 output to a logic 1. (normal default condition) Logic 1 = Set -OP1 output to a logic 0. MCR BIT-3: Logic 0 = Set -OP2 output to a logic 1. (normal default condition) Logic 1 = Set -OP2 output to a logic 0. MCR BIT-4: Logic 0 = Disable loop-back mode. (normal default condition) Logic 1 = Enable local loop-back mode (diagnostics). MCR BIT-5: Not used. MCR BIT-6: Logic 0 = Enable Modem receive and transmit input/ output interface. (normal default condition) Logic 1 = Enable infrared IrDA receive and transmit
LCR Bit-5 X 0 0 1 1
LCR Bit-4 X 0 1 0 1
LCR Bit-3 0 1 1 1 1
Parity selection
No parity Odd parity Even parity Force parity "1" Forced parity "0"
LCR BIT-6: When enabled the Break control bit causes a break condition to be transmitted (the TX output is forced to a logic 0 state). This condition exists until disabled by setting LCR bit-6 to a logic 0. Logic 0 = No TX break condition. (normal default condition) Logic 1 = Forces the transmitter output (TX) to a logic 0 for alerting the remote receiver to a line break condition.
Rev. 1.20
22
ST16C580
inputs/outputs. While in this mode, the TX/RX output/ Inputs are routed to the infrared encoder/decoder. The data input and output levels will conform to the IrDA infrared interface requirement. As such, while in this mode the infrared TX output will be a logic 0 during idle data conditions.
LSR BIT-3: Logic 0 = No framing error (normal default condition). Logic 1 = Framing error. The receive character did not have a valid stop bit(s). In the FIFO mode this error is associated with the character at the top of the FIFO. LSR BIT-4: Logic 0 = No break condition (normal default condition) Logic 1 = The receiver received a break signal (RX was a logic 0 for one character frame time). In the FIFO mode, only one break character is loaded into the FIFO. LSR BIT-5: This bit is the Transmit Holding Register Empty indicator. This bit indicates that the UART is ready to accept a new character for transmission. In addition, this bit causes the UART to issue an interrupt to CPU when the THR interrupt enable is set. The THR bit is set to a logic 1 when a character is transferred from the transmit holding register into the transmitter shift register. The bit is reset to logic 0 concurrently with the loading of the transmitter holding register by the CPU. In the FIFO mode this bit is set when the transmit FIFO is empty; it is cleared when at least 1 byte is written to the transmit FIFO. LSR BIT-6: This bit is the Transmit Empty indicator. This bit is set to a logic 1 whenever the transmit holding register and the transmit shift register are both empty. It is reset to logic 0 whenever either the THR or TSR contains a data character. In the FIFO mode this bit is set to one whenever the transmit FIFO and transmit shift register are both empty. LSR BIT-7: Logic 0 = No Error (normal default condition) Logic 1 = At least one parity error, framing error or break indication is in the current FIFO data. This bit is cleared when LSR register is read.
Modem Status Register (MSR) This register provides the current state of the control interface signals from the modem, or other peripheral
MCR BIT-7: Logic 0 = Divide by one. The input clock (crystal or external) is divided by sixteen and then presented to the Programmable Baud Rate Generator (BGR) without further modification, i.e., divide by one. (normal, default condition) Logic 1 = Divide by four. The divide by one clock described in MCR bit-7 equals a logic 0, is further divided by four (also see Programmable Baud Rate Generator section).
Line Status Register (LSR) This register provides the status of data transfers between. the 580 and the CPU.
LSR BIT-0: Logic 0 = No data in receive holding register or FIFO. (normal default condition) Logic 1 = Data has been received and is saved in the receive holding register or FIFO. LSR BIT-1: Logic 0 = No overrun error. (normal default condition) Logic 1 = Overrun error. A data overrun error occurred in the receive shift register. This happens when additional data arrives while the FIFO is full. In this case the previous data in the shift register is overwritten. Note that under this condition the data byte in the receive shift register is not transfer into the FIFO, therefore the data in the FIFO is not corrupted by the error. LSR BIT-2: Logic 0 = No parity error (normal default condition) Logic 1 = Parity error. The receive character does not have correct parity information and is suspect. In the FIFO mode, this error is associated with the character at the top of the FIFO.
Rev. 1.20
23
ST16C580
device that the 580 is connected to. Four bits of this register are used to indicate the changed information. These bits are set to a logic 1 whenever a control input from the modem changes state. These bits are set to a logic 0 whenever the CPU reads this register.
MSR BIT-5: DSR (active high, logical 1). Normally this bit is the compliment of the -DSR input. In the loop-back mode, this bit is equivalent to the DTR bit in the MCR register. MSR BIT-6: RI (active high, logical 1). Normally this bit is the compliment of the -RI input. In the loop-back mode this bit is equivalent to the OP1 bit in the MCR register. MSR BIT-7: CD (active high, logical 1). Normally this bit is the compliment of the -CD input. In the loop-back mode this bit is equivalent to the OP2 bit in the MCR register.
Scratchpad Register (SPR) The ST16C580 provides a temporary data register to store 8 bits of user information. Enhanced Feature Register (EFR) Enhanced features are enabled or disabled using this register. Bits-0 through 4 provide single or dual character software flow control selection. When the Xon1 and Xon2 and/or Xoff1 and Xoff2 modes are selected, the double 8-bit words are concatenated into two sequential characters.
MSR BIT-0: Logic 0 = No -CTS Change (normal default condition) Logic 1 = The -CTS input to the 580 has changed state since the last time it was read. A modem Status Interrupt will be generated.
MSR BIT-1: Logic 0 = No -DSR Change (normal default condition) Logic 1 = The -DSR input to the 580 has changed state since the last time it was read. A modem Status Interrupt will be generated.
MSR BIT-2: Logic 0 = No -RI Change (normal default condition) Logic 1 = The -RI input to the 580 has changed from a logic 0 to a logic 1. A modem Status Interrupt will be generated.
MSR BIT-3: Logic 0 = No -CD Change (normal default condition) Logic 1 = Indicates that the -CD input to the has changed state since the last time it was read. A modem Status Interrupt will be generated. MSR BIT-4: -CTS functions as hardware flow control signal input if it is enabled via EFR bit-7. The transmit holding register flow control is enabled/disabled by MSR bit-4. Flow control (when enabled) allows the starting and stopping the transmissions based on the external modem -CTS signal. A logic 1 at the -CTS pin will stop 580 transmissions as soon as current character has finished transmission.
Normally MSR bit-4 bit is the compliment of the -CTS input. However in the loop-back mode, this bit is equivalent to the RTS bit in the MCR register.
EFR BIT 0-3: (logic 0 or cleared is the default condition) Combinations of software flow control can be selected by programming these bits.
Rev. 1.20
24
ST16C580
Table 7, SOFTWARE FLOW CONTROL FUNCTIONS Cont-3 0 1 0 1 X X X 1 Cont-2 0 0 1 1 X X X 0 Cont-1 X X X X 0 1 0 1 Cont-0 X X X X 0 0 1 1 TX, RX software flow controls No transmit flow control Transmit Xon1/Xoff1 Transmit Xon2/Xoff2 Transmit Xon1 and Xon2/Xoff1 and Xoff2 No receive flow control Receiver compares Xon1/Xoff1 Receiver compares Xon2/Xoff2 Transmit Xon1/ Xoff1. Receiver compares Xon1 and Xon2, Xoff1 and Xoff2 Transmit Xon2/Xoff2 Receiver compares Xon1 and Xon2/Xoff1 and Xoff2 Transmit Xon1 and Xon2/Xoff1 and Xoff2 Receiver compares Xon1 and Xon2/Xoff1 and Xoff2 No transmit flow control Receiver compares Xon1 and Xon2/Xoff1 and Xoff2
0 1 0
1 1 0
1 1 1
1 1 1
EFR BIT-4: Enhanced function control bit. The content of the IER bits 4-7, ISR bits 4-5, FCR bits 4-5, and MCR bits 5-7 can be modified and latched. After modifying any bits in the enhanced registers, EFR bit-4 can be set to a logic 0 to latch the new values. This feature prevents existing software from altering or overwriting the 580 enhanced functions.
Logic 0 = disable/latch enhanced features. IER bits 47, ISR bits 4-5, FCR bits 4-5, and MCR bits 5-7 are saved to retain the user settings, then IER bits 4-7, ISR bits 4-5, FCR bits 4-5, and MCR bits 5-7 are initialized to the default values shown in the Internal Resister Table. After a reset, the IER bits 4-7, ISR bits 4-5, FCR bits 4-5, and MCR bits 5-7 are set to a logic 0 to be compatible with ST16C550 mode. (normal default condition). Logic 1 = Enables the enhanced functions. When this bit is set to a logic 1 all enhanced features of the 580 are enabled and user settings stored during a reset will be restored.
EFR BIT-5: Logic 0 = Special Character Detect Disabled (normal default condition) Logic 1 = Special Character Detect Enabled. The 580 compares each incoming receive character with Xoff2 data. If a match exists, the received data will be transferred to FIFO and ISR bit-4 will be set to indicate detection of special character. Bit-0 in the X-registers corresponds with the LSB bit for the receive character. When this feature is enabled, the normal software flow control must be disabled (EFR bits 0-3 must be set to a logic 0). EFR BIT-6: Automatic RTS may be used for hardware flow control by enabling EFR bit-6. When AUTO RTS is selected, an interrupt will be generated when the receive FIFO is filled to the programmed trigger level and -RTS will go to a logic 1 at the next trigger level. -RTS will return to a logic 0 when data is unloaded below the next lower trigger level (Programmed trigger level -1). The state of this register bit changes with the status of the
Rev. 1.20
25
ST16C580
hardware flow control. -RTS functions normally when hardware flow control is disabled. 0 = Automatic RTS flow control is disabled. (normal default condition) 1 = Enable Automatic RTS flow control.
SIGNALS TX -OP1 -OP2 -RTS -DTR -RXRDY -TXRDY INT
RESET STATE Logic 1 Logic 1 Logic 1 Logic 1 Logic 1 Logic 1 Logic 0 Logic 0
EFR bit-7: Automatic CTS Flow Control. Logic 0 = Automatic CTS flow control is disabled. (normal default condition) Logic 1 = Enable Automatic CTS flow control. Transmission will stop when -CTS goes to a logical 1. Transmission will resume when the -CTS pin returns to a logical 0.
ST16C580 EXTERNAL RESET CONDITIONS REGISTERS IER ISR LCR, MCR LSR RESET STATE IER BITS 0-7 = logic 0 ISR BIT-0=1, ISR BITS 1-7 = logic 0 BITS 0-7 = logic 0 LSR BITS 0-4 = logic 0, LSR BITS 5-6 = logic 1 LSR, BIT 7 = logic 0 MSR BITS 0-3 = logic 0, MSR BITS 4-7 = logic levels of the input signals BITS 0-7 = logic 0
MSR
FCR, EFR
Rev. 1.20
26
ST16C580
AC ELECTRICAL CHARACTERISTICS
TA=0 - 70C (-40 - +85C for Industrial grade packages), Vcc=3.3 - 5.0 V 10% unless otherwise specified. Symbol Parameter Limits 3.3 Min Max 17 8 35 5 5 5 0 10 35 0 10 40 15 35 25 10 40 0 10 40 20 5 50 40 40 1 45 45 24 45 1 45 45 8 40 1 216-1 40 1 10 25 0 10 30 15 5 40 35 35 1 40 40 24 40 1 40 40 8 216-1 25 0 5 0 0 10 25 0 10 30 10 25 15 Limits 5.0 Min Max 17 24 Units Conditions
T1w,T2w T3w T4w T5s T5h T6s T6h T7d T7w T7h T8d T9d T11d T12d T12h T13d T13w T13h T14d T15d T16s T16h T17d T18d T19d T20d T21d T22d T23d T24d T25d T26d T27d T28d TR N
Clock pulse duration Oscillator/Clock frequency Address strobe width Address setup time Address hold time Address setup time Chip select hold time -IOR delay from chip select -IOR strobe width Chip select hold time from -IOR -IOR delay from address Read cycle delay -IOR to -DDIS delay Delay from -IOR to data Data disable time -IOW delay from chip select -IOW strobe width Chip select hold time from -IOW -IOW delay from address Write cycle delay Data setup time Data hold time Delay from -IOW to output Delay to set interrupt from MODEM input Delay to reset interrupt from -IOR Delay from stop to set interrupt Delay from -IOR to reset interrupt Delay from stop to interrupt Delay from initial INT reset to transmit start Delay from -IOW to reset interrupt Delay from stop to set -RxRdy Delay from -IOR to reset -RxRdy Delay from -IOW to set -TxRdy Delay from start to reset -TxRdy Reset pulse width Baud rate devisor
ns MHz ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns Rclk ns ns Rclk ns Rclk ns ns Rclk ns Rclk
Note 1: Note 1: Note 1: 100 pF load
Note 1:
Note 1:
100 pF load 100 pF load 100 pF load 100 pF load
8
8
Note 1: Applicable only when -AS is tied low.
Rev. 1.20
27
ST16C580
ABSOLUTE MAXIMUM RATINGS
Supply range Voltage at any pin Operating temperature Storage temperature Package dissipation 7 Volts GND - 0.3 V to VCC +0.3 V -40 C to +85 C -65 C to 150 C 500 mW
DC ELECTRICAL CHARACTERISTICS
TA=0 - 70C (-40 - +85C for Industrial grade packages), Vcc=3.3 - 5.0 V 10% unless otherwise specified. Symbol Parameter Limits 3.3 Min Max -0.3 2.4 -0.3 2.0 0.6 VCC 0.8 Limits 5.0 Min Max -0.5 3.0 -0.5 2.2 0.6 VCC 0.8 VCC 0.4 Units Conditions
VILCK VIHCK VIL VIH VOL VOL VOH VOH IIL ICL I CC CP
Clock input low level Clock input high level Input low level Input high level Output low level on all outputs Output low level on all outputs Output high level Output high level Input leakage Clock leakage Avg power supply current Input capacitance
0.4 2.4 2.0 10 10 1.3 5 10 10 3 5
V V V V V V V V A A mA pF
IOL= 5 mA IOL= 4 mA IOH= -5 mA IOH= -1 mA
Rev. 1.20
28
ST16C580
T2w
T1w
EXTERNAL CLOCK
T3w
-BAUDOUT
1/2 -BAUDOUT
1/3 -BAUDOUT
1/3> -BAUDOUT X450-CK-1
Clock timing
Rev. 1.20
29
ST16C580
T4w -AS T5s A0-A2 Valid Address T6s -CS2 CS1-CS0 T7d T8d -IOR IOR Valid T7w Active T7h T9d T6h T5h
T11d -DDIS T12d D0-D7 Data Active
T11d
T12h
X550-RD-1
General read timing
Rev. 1.20
30
ST16C580
T4w -AS T5s A0-A2 Valid Address T6s -CS2 CS1-CS0 T13d T14d -IOW IOW Valid T13w Active T16s T16h T13h T15d T6h T5h
D0-D7
Data X550-WD-1
General write timing
Rev. 1.20
31
ST16C580
-IOW IOW
Active T17d
-RTS -DTR
Change of state
Change of state
-CD -CTS -DSR T18d INT
Change of state
Change of state
T18d Active T19d Active Active
-IOR IOR
Active
Active
Active
T18d -RI Change of state X450-MD-1
Modem input/output timing
Rev. 1.20
32
ST16C580
START BIT
DATA BITS (5-8)
STOP BIT
RX
D0
D1
D2
D3
D4
D5
D6
D7 PARITY BIT NEXT DATA START BIT T20d Active T21d
5 DATA BITS 6 DATA BITS 7 DATA BITS
INT
-IOR IOR
16 BAUD RATE CLOCK
X450-RX-1
Receive timing
Rev. 1.20
33
ST16C580
START BIT
DATA BITS (5-8)
STOP BIT
RX
D0
D1
D2
D3
D4
D5
D6
D7 PARITY BIT NEXT DATA START BIT T25d
-RXRDY
Active Data Ready T26d
-IOR IOR
Active
X550-RX-2
Receive ready timing in none FIFO mode
Rev. 1.20
34
ST16C580
START BIT
DATA BITS (5-8)
STOP BIT
RX
D0
D1
D2
D3
D4
D5
D6
D7 PARITY BIT First byte that reaches the trigger level T25d
-RXRDY
Active Data Ready T26d
-IOR IOR
Active
X550-RX-3
Receive ready timing in FIFO mode
Rev. 1.20
35
ST16C580
START BIT
DATA BITS (5-8)
STOP BIT
TX
D0
D1
D2
D3
D4
D5
D6
D7 PARITY BIT NEXT DATA START BIT T22d Active Tx Ready
5 DATA BITS 6 DATA BITS 7 DATA BITS
INT T23d -IOW IOW Active
T24d
Active
16 BAUD RATE CLOCK
X450-TX-1
Transmit timing
Rev. 1.20
36
ST16C580
START BIT
DATA BITS (5-8)
STOP BIT
TX
D0
D1
D2
D3
D4
D5
D6
D7 PARITY BIT NEXT DATA START BIT
-IOW IOW
Active
BYTE #1 T27d -TXRDY Active Transmitter ready
T28d
Transmitter not ready X550-TX-2
Transmit ready timing in none FIFO mode
Rev. 1.20
37
ST16C580
START BIT DATA BITS (5-8) STOP BIT
TX
D0
D1
D2
D3
D4
D5
D6
D7
5 DATA BITS 6 DATA BITS 7 DATA BITS
PARITY BIT
-IOW IOW
Active T28d
D0-D7
BYTE #16
T27d -TXRDY FIFO Full X550-TX-3
Transmit ready timing in FIFO mode
Rev. 1.20
38
ST16C580
UART Frame Start Data Bits 1 0 1 0 0 1 1 0 Stop 1 1/2 Bit Time 3/16 Bit Time 0-1 16x clock delay 0 1 0 0 1 1 0 1 Stop
X650-IR-1
TX
0
IRTX Bit Time
Infrared transmit timing
IRRX Bit Time
RX
0 Start
1
Data Bits UART Frame
Infrared receive timing
Rev. 1.20
39
ST16C580
PACKAGE OUTLINE DRAWING
48 LEAD THIN QUAD FLAT PACK (TQFP)
D D1 36 25
37
24
D1
D
48
13
1 B A2 e
1 2
C A Seating Plane A1 L
Note: The control dimension is the millimeter column
SYMBOL A A1 A2 B C D D1 e L 0 INCHES MIN 0.039 0.002 0.037 0.007 0.004 0.346 0.272 0.018 MAX 0.047 0.006 0.041 0.011 0.008 0.362 0.280 0.030 7 MILLIMETERS MIN 1.00 0.05 0.95 0.17 0.09 8.80 6.90 0.45 0 MAX 1.20 0.15 1.05 0.27 0.20 9.20 7.10 0.75 7
0.20 BSC
0.50BSC
Rev. 1.20
40
ST16C580
EXPLANATION OF DATA SHEET REVISIONS: FROM 1.10 TO 1.20 CHANGES Added Patent Number. Added revision history. Added Device Status to front page. DATE Sept 2003
NOTICE EXAR Corporation reserves the right to make changes to the products contained in this publication in order to improve design, performance or reliability. EXAR Corporation assumes no responsibility for the use of any circuits described herein, conveys no license under any patent or other right, and makes no representation that the circuits are free of patent infringement. Charts and schedules contained here in are only for illustration purposes and may vary depending upon a user's specific application. While the information in this publication has been carefully checked; no responsibility, however, is assumed for inaccuracies. EXAR Corporation does not recommend the use of any of its products in life support applications where the failure of the product can reasonably be expected to cause failure of the life support system or to significantly affect its safety or effectiveness. Products are not authorized for use in such applications unless EXAR Corporation receives, in writing, assurances to its satisfaction that: (a) the risk of injury or damage has been minimized; (b) the user assumes all such risks; (c) potential liability of EXAR Corporation is adequately protected under the circumstances. Copyright 2003 EXAR Corporation Datasheet September 2003 Send your UART technical inquiry with technical details to hotline: uarttechsupport@exar.com Reproduction, in part or whole, without prior written consent of EXAR Corporation is prohibited. Rev. 1.20
41


▲Up To Search▲   

 
Price & Availability of ST16C580

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X